What a Plate Basket Centrifuge Is
A plate basket centrifuge is a batch filtering centrifuge built on a flat plate base: the basket sits in a short, rigid frame instead of on the three legs of a conventional hanging machine, and the whole unit is bolted to the floor without a separate foundation. On the LYW plate basket separator the drive is a frequency converter for stepless speed regulation, a PLC sequence handles the start and stop ramps, there is a main control cabinet plus a field-mounted auxiliary panel, and the shell flips open so the basket and the space behind it can be washed directly. Cake leaves in a lift-out filter bag, which can be taken away from the machine for off-site discharge.
The consequence that matters commercially is that this machine separates by screening, not by density. A filter medium — bag or cloth — is stretched in the basket, the basket spins, and the liquid is pushed through the medium while particles larger than its openings stay behind as cake. Everything about selection follows from that one sentence.
No capacity figure is quoted here. The technical parameter block on the Plate Basket Centrifuge Separator page is a drawing, and throughput is settled by a trial on the actual slurry. What follows is how to judge whether your slurry belongs in this machine at all.
Screening, Not Settling
Two families of centrifuge look similar on a shop floor and behave completely differently. A decanter or a disc stack separator throws solids outward or holds them on discs by density difference: a light particle the same size as a heavy one travels a different path, and a particle smaller than the separation cut simply leaves with the liquid. A basket machine with filter media does not care about density at all. It cares whether the particle is bigger than the pore it is being pushed against.
That produces three practical rules:
- Particle size decides feasibility, not density. Fine crystals of a dense salt can pass a medium that retains coarse flakes of a light pigment.
- The cake becomes the filter. Once a layer forms, retention improves sharply because the cake itself filters. Early filtrate is always dirtier than steady-state filtrate.
- Shape matters as much as size. Needles and plates bridge over a medium and blind it; round crystals of the same nominal size drain freely.
If the solids are the product and must be captured dry, this family is the natural candidate. If the solids are a nuisance that has to be thickened and pumped away, a settling machine usually does the job with less labour.
The Slurry Groups It Handles
The published application list for this machine is broad, and it is easier to read grouped than as a list. The grouping below follows the product page’s own material names.
| Group | Materials named on the product page | What the machine is doing |
|---|---|---|
| Crystalline salts | Glauber’s salt, copper sulfate, nickel sulfate, borax, soda, salt, thiamine | Dewatering a crystal crop that must stay a solid product |
| Pigments and dyes | Dye, plastic raw materials, rubber additives, resins | Washing and dewatering a cake where colour and purity carry the price |
| Pharmaceutical and food | Antibiotics and other drugs, vitamins, MSG, food additives, starch sugar | Contained batch duty with cleanable contact surfaces |
| Minerals and metal | Copper, zinc, aluminium ore dehydration; metal refining; gypsum | Bulk dewatering ahead of drying or shipping |
| Agrochemical and water treatment | Herbicides, insect repellents, water treatment sludge | Handling material that must not escape the machine |
| Fibrous and viscous | Fibrous material and high-viscosity feeds generally | Retaining solids that would blind or pass other equipment |
The page also names acetic acid and oil, which are liquid duties rather than cake duties — in those cases the machine is being used for the separation step, not for producing a dry solid.
Particle Size and Filter Media
Media choice is the only real tuning knob on the filtration side, and it is usually a compromise. A tight medium retains fine solids and produces clear filtrate, but it blinds quickly and lengthens the batch cycle. An open medium drains fast and lets fines through. Typical retention for woven filter cloths sits in the range of a few microns up to a few tens of microns depending on weave and finish; these are typical ranges for the medium, not a guarantee for your slurry.
Two habits make media selection cheap. First, ask for a filtrate clarity target in writing — “clear” is not a specification, and the cost of the last few microns is a much shorter cycle. Second, keep the first filtrate separate from the steady-state filtrate: the initial pass through a clean medium carries fines that the cake afterwards removes, and blending the two makes a clear stream look cloudy.
Fibrous and High-Viscosity Feeds
Fibrous material is the case where a basket machine beats most alternatives, because the fibres form a mat that holds itself on the medium. The failure mode is different from that of crystals: instead of passing, the feed blinds the surface and the drainage rate collapses part way through the batch.
For viscous feeds the limiting factor is not the centrifuge but the feed itself. Thick slurry does not distribute evenly across the basket wall; it climbs one side and leaves the other dry, which shows up as an unbalanced load and a cake of uneven thickness. Diluting, heating, or feeding in stages during the ramp are the usual remedies. If the material has to be fed at full consistency, a settling machine that tolerates thick feed is the better conversation.
Toxic, Flammable and Hazardous Duty
The published application list explicitly includes toxic and hazardous material and flammable material, which is a statement about containment rather than about separation. A batch filtering centrifuge is a good containment device because the process is closed between feed and discharge and the cake leaves as a solid, not as an aerosol.
That only holds if the accessories are right. For flammable solvents, the motor and electrical fittings, the grounding path to the basket, and inert gas blanketing over the cake are the items that decide whether the installation is acceptable, not the basket itself. For toxic solids, the lift-out bag is what makes the difference: the cake leaves the machine inside the bag and is handled off-site, so the operator never opens a loaded basket in the room.
Because the shell flips open and the basket is fully exposed, this machine can be washed and sterilised to the standard that pharmaceutical and food duty require — but the washdown routine belongs to a separate topic, covered in the basket centrifuge discharge and washdown guide.
Where It Stops: Hand-Off Points
A basket machine is batch and it is filtration. Both facts create clear boundaries; crossing them costs throughput or product quality.
| Condition | Why the basket machine stops working | Machine to look at instead |
|---|---|---|
| Solids are a small fraction of a large continuous flow | Batch cycle cannot keep up with continuous feed | Two phase decanter centrifuge |
| Particles are finer than any practical medium | Passes the medium or blinds it immediately | Disc stack separator, clarification duty |
| Very large cake tonnage with low added value | Labour per batch dominates the cost | Plate and frame filter press |
| Product needs the gentlest possible handling | Centrifugal force compacts and can break the cake | Pressure filtration |
| Cake must be washed to a tight specification | Wash liquid channels through the cake unevenly | Reslurry washing, or a pressure filter with controlled wash |
The neighbouring plate filter centrifuge separator is the closer relative, and the SS series dewatering filter centrifuge is the other common starting point for chemical slurry. Differences between them sit in discharge method and basket geometry rather than in the separation principle; the peeler variant’s cycle is described in the plate peeler batch cycle guide.
Prove It on Your Own Slurry
Media selection cannot be finished on paper. A basket test on a real sample settles it in an afternoon, and six numbers come out of it:
- Filtration rate against time, so the cycle length is known rather than estimated.
- Filtrate clarity at the start and at steady state, kept as two separate samples.
- Cake thickness after a fixed feed volume.
- Residual moisture after a fixed spin time, measured by drying a sample, not by feel.
- Whether the cake releases from the medium, or sticks and has to be scraped.
- Whether the medium blinds — repeat the same test three times and compare rates.
For reference, the centrifugal acceleration that drives drainage is G = rω²/g (calculated), where r is the basket radius and ω the angular velocity, so acceleration rises with the square of speed. Doubling basket speed quadruples the driving force — which is why a test at reduced speed understates performance, and why the test should be run at the speed the machine will actually use.
Batch sizing itself — how many kilograms per cycle and how many cycles per shift — depends on cake volume and cake thickness together, which is the subject of the throughput and cake thickness guide. Get the slurry test right first; sizing is arithmetic afterwards.
FAQ
Can it separate a slurry whose solids are lighter than the liquid?
Yes, if the particles are retained by the medium. Filtration does not depend on density difference, so a light solid that floats in a settling machine can still be captured on a filter bag.
Does it need a foundation?
The plate design is intended to be installed without one, with a damping system taking the vibration instead of a concrete block. The floor still has to be level and able to carry the loaded weight, and the isolators have to be set as specified.
Why is the first filtrate cloudy?
Because a clean medium does not yet have a cake on it. Retention improves as the cake builds. Judge the medium on steady-state clarity, and recirculate the first pass if clarity is a product requirement.
Is a lift-out bag a disadvantage?
It costs operator time per batch and it is a consumable. What it buys is that the cake leaves the room inside the bag, which is usually decisive for toxic or API duty, and it removes the need to scrape a loaded basket by hand.